If you have been searching for 200046 AND 476314 of Switch Flow components with NSN 5930004515772 under FSC 5930 Switches, look no further than Limitless Aerospace. 200046 AND 476314 part is listed alongside the other Switch Flow parts, and it has been manufactured by Rotron Inc (CAGE Code 82877). With current availability through our website, we invite you to request a quick and competitive quote for 200046 AND 476314 by filling out and submitting the RFQ form below. By providing us with information such as your target price and when you need your parts by, we can ensure that we offer a personalized solution that accommodates your individual needs and requirements.
NSN parts are those that follow the NSN system as dictated by the NATO Standardization Agreements, and they contain a 13-digit serial number to optimize the procurement, stocking, and issuing of items through the federal supply system. On Limitless Aerospace, we make finding the NSN parts and components you need easy, and customers may peruse our robust NSN part catalogues or use our search engine to find specific items with ease. As the only independent distributor with a no China sourcing pledge, we choose to only stock items from top global manufacturers such as Rotron Inc. Get started on the purchasing process for 200046 AND 476314 today and see how we can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-451-5772 Item Description: Switch Flow | 5930 | 004515772 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
200046 And 476314 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.844 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.646 INCHES MINIMUM AND 0.666 INCHES MAXIMUM |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.490 INCHES MINIMUM AND 0.510 INCHES MAXIMUM |
AWTN | OPERATING TEMP RATING | 55.0 DEG CELSIUS MAXIMUM AND 0.0 DEG CELSIUS MINIMUM |
AXGY | MOUNTING METHOD | STRAP |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | TAB, SOLDER LUG |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 2270.00 ACTUATION POINT NOMINAL FEET PER MINUTE AND 2035.00 DEACTUATION POINT NOMINAL FEET PER MINUTE AND 235.00 DIFFERENTIAL POINT NOMINAL FEET PER MINUTE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL SINGLE VOLTAGE |