If you have been searching for 002-008C001 of Switch Liquid Level components with NSN 5930004515976 under FSC 5930 Switches, look no further than Limitless Aerospace. 002-008C001 part is listed alongside the other Switch Liquid Level parts, and it has been manufactured by M J Industries Inc (CAGE Code 64703). With current availability through our website, we invite you to request a quick and competitive quote for 002-008C001 by filling out and submitting the RFQ form below. By providing us with information such as your target price and when you need your parts by, we can ensure that we offer a personalized solution that accommodates your individual needs and requirements.
NSN parts are those that follow the NSN system as dictated by the NATO Standardization Agreements, and they contain a 13-digit serial number to optimize the procurement, stocking, and issuing of items through the federal supply system. On Limitless Aerospace, we make finding the NSN parts and components you need easy, and customers may peruse our robust NSN part catalogues or use our search engine to find specific items with ease. As the only independent distributor with a no China sourcing pledge, we choose to only stock items from top global manufacturers such as M J Industries Inc. Get started on the purchasing process for 002-008C001 today and see how we can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-451-5976 Item Description: Switch Liquid Level | 5930 | 004515976 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
002-008c001 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 6.000 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 110.0 VOLTS NOMINAL 1ST OPERATING POWER RQMT |
ACYN | AC VOLTAGE RATING | 220.0 VOLTS NOMINAL 2ND OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | 32.0 VOLTS NOMINAL 4TH OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | 6.0 VOLTS NOMINAL 3RD OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
ADAV | OVERALL DIAMETER | 3.000 INCHES NOMINAL |
AFLW | ACTUATION METHOD | BUOYANCY |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 45.0 MILLIAMPERES RESISTIVE LOAD |
AWAE | FLOAT QUANTITY | 1 |
AXGY | MOUNTING METHOD | THREAD |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD |
BJKD | CONTACT ARRANGEMENT | SINGLE THROW,NORMALLY OPEN |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | FUEL, NONAIRCRAFT AND HYDRAULIC OIL AND WATER |
BJKP | MOUNTING DIMENSIONS | MTD BY 3/4 IN.PIPE THD CONNECTIONS AT INLET AND OUTLET |
FAAZ | PHASE | SINGLE |
FEAT | SPECIAL FEATURES | 24.000 IN. MIN,26.000 IN. MAX LG WIRE LEADCONNECTIONS |