If you have been searching for 500471-1 of Transformer Assembl components with NSN 5950013186661 under FSC 5950 Coils and Transformers, look no further than Limitless Aerospace. 500471-1 part is listed alongside the other Transformer Assembl parts, and it has been manufactured by General Dynamics Ots Inc (CAGE Code 21562). With current availability through our website, we invite you to request a quick and competitive quote for 500471-1 by filling out and submitting the RFQ form below. By providing us with information such as your target price and when you need your parts by, we can ensure that we offer a personalized solution that accommodates your individual needs and requirements.
NSN parts are those that follow the NSN system as dictated by the NATO Standardization Agreements, and they contain a 13-digit serial number to optimize the procurement, stocking, and issuing of items through the federal supply system. On Limitless Aerospace, we make finding the NSN parts and components you need easy, and customers may peruse our robust NSN part catalogues or use our search engine to find specific items with ease. As the only independent distributor with a no China sourcing pledge, we choose to only stock items from top global manufacturers such as General Dynamics Ots Inc. Get started on the purchasing process for 500471-1 today and see how we can serve as your strategic sourcing partner for all of your operational needs.
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.390 INCHES MINIMUM AND 2.430 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.730 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.770 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.410 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.450 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.068 INCHES MINIMUM AND 5.088 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 195.5 VOLT-AMPERE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL ALL COMPONENTS |
AEHZ | MAXIMUM OPERATING TEMP | 104.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 1.7 AMPERES AC NOMINAL ALL COMPONENTS SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 640.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 75.0 MILLIAMPERES AC MINIMUM 1ST COMPONENT 2ND SECONDARY AND 400.0 MILLIAMPERES AC MAXIMUM 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.700 ALL COMPONENTS SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.7932 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 4.300 2ND COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 52.200 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 7.800 1ST COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 19.44 VOLTS-AMPERES 1ST COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 195.5 VOLTS-AMPERES ALL COMPONENTS SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 45.824 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.70 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 56.90 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY AND 71.60 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 24.30 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 25.60 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 26.20 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS ALL SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
ABMK | OVERALL WIDTH | 2.117 INCHES MINIMUM AND 2.217 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.115 INCHES MINIMUM SINGLE GROUP AND 0.135 INCHES MAXIMUM SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 2 SECONDARY 1ST COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.0886 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.540 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 2.4 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 44.96 VOLTS-AMPERES 1ST COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL ALL COMPONENTS SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 30 TURRET |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 2.56 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 2.62 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 159.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 33.85 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 38.30 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 41.50 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 70.90 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY AND 74.10 AC VOLTS NOMIN |
TEST | TEST DATA DOCUMENT | 16340-11-00151 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |