If you have been searching for 812123 of Capacitor Fixed Cer components with NSN 5910013245822 under FSC 5910 Capacitors, look no further than Limitless Aerospace. 812123 part is listed alongside the other Capacitor Fixed Cer parts, and it has been manufactured by Fluke Corporation (CAGE Code 89536). With current availability through our website, we invite you to request a quick and competitive quote for 812123 by filling out and submitting the RFQ form below. By providing us with information such as your target price and when you need your parts by, we can ensure that we offer a personalized solution that accommodates your individual needs and requirements.
NSN parts are those that follow the NSN system as dictated by the NATO Standardization Agreements, and they contain a 13-digit serial number to optimize the procurement, stocking, and issuing of items through the federal supply system. On Limitless Aerospace, we make finding the NSN parts and components you need easy, and customers may peruse our robust NSN part catalogues or use our search engine to find specific items with ease. As the only independent distributor with a no China sourcing pledge, we choose to only stock items from top global manufacturers such as Fluke Corporation. Get started on the purchasing process for 812123 today and see how we can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-324-5822 Item Description: Capacitor Fixed Cer | 5910 | 013245822 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
812123 | B | 1 | C | A |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
ABJT | TERMINAL LENGTH | 1.250 INCHES MINIMUM |
ADAT | BODY WIDTH | 0.160 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.085 INCHES MINIMUM AND 0.115 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.024 INCHES MINIMUM AND 0.029 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
CQBQ | CAPACITANCE VALUE PER SECTION | 47.000 PICOFARADS SINGLE SECTION |
CQLZ | III TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 200.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -30.0/+30.0 SINGLE SECTION |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-20 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-C-20/39 GOVERNMENT SPECIFICATION |
CWJK | CASE MATERIAL | PLASTIC |
ADAQ | BODY LENGTH | 0.160 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.065 INCHES MINIMUM AND 0.115 INCHES MAXIMUM |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
CRTP | TOLERANCE RANGE PER SECTION | -2.00/+2.00 PERCENT SINGLE SECTION |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 0.150 |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote