If you have been searching for L04292 of Transformer Power components with NSN 5950013234882 under FSC 5950 Coils and Transformers, look no further than Limitless Aerospace. L04292 part is listed alongside the other Transformer Power parts, and it has been manufactured by Dla Land And Maritime (CAGE Code 16236). With current availability through our website, we invite you to request a quick and competitive quote for L04292 by filling out and submitting the RFQ form below. By providing us with information such as your target price and when you need your parts by, we can ensure that we offer a personalized solution that accommodates your individual needs and requirements.
NSN parts are those that follow the NSN system as dictated by the NATO Standardization Agreements, and they contain a 13-digit serial number to optimize the procurement, stocking, and issuing of items through the federal supply system. On Limitless Aerospace, we make finding the NSN parts and components you need easy, and customers may peruse our robust NSN part catalogues or use our search engine to find specific items with ease. As the only independent distributor with a no China sourcing pledge, we choose to only stock items from top global manufacturers such as Dla Land And Maritime. Get started on the purchasing process for L04292 today and see how we can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-323-4882 Item Description: Transformer Power | 5950 | 013234882 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
L04292 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 2.312 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 3.120 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.060 INCHES NOMINAL |
ACZB | FREQUENCY RATING | 57.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 20.0 VOLT-AMPERE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 105.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
CRBZ | WINDING OPERATING CURRENT | 0.3 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 30.50 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE ELECTRONICS SUPPLY CENTER PRODUCTION STANDARD NO. L04292; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY; TERMINALS4 AND 5 CONNECTED,TERMINALS6 AND 7 CONNECTED |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK AND 2 WIRE LEAD |
CRMJ | WINDING POWER RATING | 7.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CRMJ | WINDING POWER RATING | 6.9 VOLTS-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 440.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.
Request for Quote