If you have been searching for 8434943-001 of Transformer Power components with NSN 5950011745212 under FSC 5950 Coils and Transformers, look no further than Limitless Aerospace. 8434943-001 part is listed alongside the other Transformer Power parts, and it has been manufactured by Cohu Inc (CAGE Code 05157). With current availability through our website, we invite you to request a quick and competitive quote for 8434943-001 by filling out and submitting the RFQ form below. By providing us with information such as your target price and when you need your parts by, we can ensure that we offer a personalized solution that accommodates your individual needs and requirements.
NSN parts are those that follow the NSN system as dictated by the NATO Standardization Agreements, and they contain a 13-digit serial number to optimize the procurement, stocking, and issuing of items through the federal supply system. On Limitless Aerospace, we make finding the NSN parts and components you need easy, and customers may peruse our robust NSN part catalogues or use our search engine to find specific items with ease. As the only independent distributor with a no China sourcing pledge, we choose to only stock items from top global manufacturers such as Cohu Inc. Get started on the purchasing process for 8434943-001 today and see how we can serve as your strategic sourcing partner for all of your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-174-5212 Item Description: Transformer Power | 5950 | 011745212 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
8434943-001 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKW | OVERALL HEIGHT | 2.690 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.250 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.136 INCHES MINIMUM SINGLE GROUP AND 0.140 INCHES MAXIMUM SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.150 INCHES MINIMUM AND 3.210 INCHES MAXIMUM |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.781 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.843 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
AXGY | MOUNTING METHOD | BRACKET SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CRBZ | WINDING OPERATING CURRENT | 15.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT ALL PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 550.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 207.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 35.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | THE SECOND SECONDARY WINDING IS INTERNALLY CONNECTED TO THE CENTER TAP OF THE FIRST SECONDARY WINDING; A THERMAL PROTECTOR IS INTERNALLY CONNECTED TO THE SECONDARY WINDING |
TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD |